导航

轻松数控网

致力于数控技术的网络分享 Sunlight'blog
Covering research, news, and knowledge in CNC technology and e-Learning.

« Fanuc 梯形图软件 FAPT LADDER-III V4.60下载NPT,PT,G各种螺纹的区别 »

Fanuc梯形图软件FAPT LADDER-III V2.1下载

Fanuc梯形图软件 FAPT LADDER-IIIv2.1
双击 Setup.exe 安装
下载地址:
ladder III 2.1.rar

推荐安装:Fanuc 梯形图软件 FAPT LADDER-III V5.0版 

下载地址http://www.cnctechnet.com/post/fanucladder3.html


======================
2.1  FAPT LADDER-III

    FAPT LADDER-III is a programming system for developing FANUC PMC sequence
    program. Main functions are shown below.

      1) Monitoring of ladder sequence
      2) Monitoring of signal status
      3) Monitoring of PMC status
      4) On-Line editing of ladder diagram
      5) Debugging ladder sequence
      6) Signal trace
      7) Signal analysis
      8) Saving and restoring PMC parameter
      9) Others(Off-Line editing and printing, etc.)


2.2  The version of applicable software

      1) FAPT LADDER-III
        This software runs under the following condition.
        丒Executing file disk for FAPT LADDER-III
               +-------------------+
               |    Drawing No.    |
               |-------------------+
               | A08B-9210-J505    |
               +-------------------+


2.3  Operation environment
        
     To use this software, the requirements indicated in the table below must
     be satisfied.

     +-------------------+---------------------------------------------------+
     | Computer          | IBM PC/AT COMPATIBLE                              |
     +-------------------+---------------------------------------------------+
     | CPU               | Pentium 133MHz or  better                         |
     +-------------------+---------------------------------------------------+
     | OS                | Microsoft Windows95/98/Me                         |
     |                   | Microsoft Windows NT4.0/2000              (Note 1)|
     +-------------------+---------------------------------------------------+
     | Memory            | Windows95                                         |
     |                   |      16MBytes or more(32MBytes recommended)       |
     |                   | Windows98/Me/2000/NT4.0                           |
     |                   |      24MBytes or more(32MBytes recommended)       |
     +-------------------+---------------------------------------------------+
     | Hard disk         | 20Mbytes or more free space               (Note 2)|
     +-------------------+---------------------------------------------------+
     | Graphic adapter   | VGA or higher                                     |
     +-------------------+---------------------------------------------------+
     | Printer           | The printers added by the printers settings on    |
     |                   | Windows.                                          |
     +-------------------+---------------------------------------------------+
     | Japanese language | Input system in conformity with MS-KANJI API      |
     | input system      |                                                   |
     +-------------------+---------------------------------------------------+

     (Note 1) When using this software under the WindowsNT 4.0, please install
              the "Service Pack 3" software. Please get this software from
              Microsoft Corporation.
     (Note 2) In addition, the space for storing sequence data is required.


==============================================================================
[3] Activation
==============================================================================

3.1 Starting the FAPT LADDER-III from the Windows [Programs] menu.

    [Operation]
    (1) Click the [Start] button at the Windows95/98/Me/NT4.0/2000.
    (2) Click the [Programs] menu of the [Start] menu.
    (3) Click the [FAPT LADDER-III] folder of the [Programs] menu.
    (4) Click the "FAPT LADDER-III" of the [FAPT LADDER-III] folder.
        Activate the FAPT LADDER-III and run.

==========================================================================
[4] History
==========================================================================

Edition 2.00 -> 2.10

- The selectable I/O link assignment function was added in PMC-SB7.

- Specifying the connection destination according to the command line argument became possible.

- The substitution of two or more nets of the display pane was enabled with the net of the edit pane on the ladder edit screen.

- The changing line code "@0A@" in the message data was made to be able to print changing line when the message was printed.

- If setting the printer is pushed, it is likely to become an application error on the print screen.

- When the net is not displayed in the display pane of the ladder edit screen, the ladder is destroyed by inserting or substituting the net.


Edition 1.30 -> 2.00

- In PMC-SB6, the LADDER programming with 40000 steps has been supported.

- PMC-SB7 has been supported.

- In the communication with PMC, Ethernet function has been supported.

- When opening the ladder window, window position and window size are restored.

- In Windows 95/98, the application error occurred by data table input of function instruction CODB on the ladder diagram editing screen.  It has been amended.


Edition 1.20 -> 1.30

- In the ladder diagram editing screen, the application error occurred when japanese language was entered in the address of contacts/coils and the parameter of the functional instruction.  It has been amended.

- In chinese windows, the horizontal line had taken the shape of another character on printing the ladder diagram.  It has been amended.

- In Windows 95/98/ME, the hangup occasionally occurred by scrolling the ladder diagram editing screen, when the relay comment including japanese language is displayed on the screen.  It has been amended.


Edition 1.10 -> 1.20

- The execution of plural FAPT LADDER-III at same time became possible.

- For display Payne on the ladder diagram editing screen, the change of address, contacts and coils became possible.

- The file (4 or less) which had been used recently was added to the file menu.

- The link function of the load module made by C language was added.

- The comparison function of the program with PMC I/O screen was added.

- In the compilation, the making of the memory card format file which includes the JAPANESE coil comment became possible.

- In PMC-SB6(IO-2)/PMC-SB6(STEP,IO-2), it was corrected not to be able to print the message and the step sequence.

- When the sequence program of FAPT LADDER or FAPT LADDER - 嘦 was converted into the LAD file, that compile error 乬I-E3103" might be generated.  It has been amended.

- On the data table screen of the PMC parameter, when display type (BYTE/WORD/DWORD) and display format (DEC/HEX/BCD) were changed, an application error might be generated. It has been amended.

- For display Payne on the ladder diagram editing screen, the blank line might be added before the added functional instruction. It has been amended.


Edition 1.00 -> 1.10

- The contents of the online help manual became more substantial.

- 8000 ladder steps and 12000 ladder steps are available for PMC-SA1.

- The collective ladder display function is added on the ladder monitoring and editting.

- The number of contacts of the ladder edit screens has been enhanced.

- The ladder program isn't allowed to save as the same name when the other user has already opened it.

- The Signal Trigger function was added.

- The I/O Link expansion function was added for PMC-SB6 and PMC-SB6(STEP SEQ).

- It is allowed to wait until the editting becomes enable when the other user has already opened the same program.

- The online communication can't be completed on FS15i/FS15B. It has been amended.

- The function instruction texts and the PMC address input box texts on the ladder edit screen might be displayed illegally on the English edition. It has been amended.

- FAPT LADDER-III or LEP might not end when the CNC is shut down during the communication running. It has been amended.

- The signal analysis function happens to display the data not to be set for the signal address on the parameter daialog. It has been amended.

- When FAPT LADDER-III is started by the double click of a ladder program, the status bar icons aren't updated. It has been amended.

- An application error occurs when the common item option property on the print data option setting dialog is selected on the English edition of windows NT/2000. It has been amended.

- The signal analysis function doesn't display the proper analysis when the sampling mode "Before" or "After" is set. It has been amended.

- An application error might occur when the cross-references of function instruction TMR/TMRB/CTR/DIFU/DIFD are printed. It has been amended.

- When a mnemonic file which selection item is Label/Subprogram,  Full options or Japanese-formatted data, it can't be converted to source programs. It has been amended.

- If all the net comments are deleted on the net comment edit screen, an application error is generated. It has been amended.

- After printing without displaying the preview printing, the menu might not be displayed. It has been amended.
 